|
BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content DescriptionThis document establishes the general principles for the evaluation and minimization of the effects of stray current corrosion on external surfaces of buried or immersed pipeline systems caused by AC and DC electrical interference. Other stray current effects such as overheating, and interference with welding operations are not covered in this document. A brief description of AC effects, general principles and some guidelines, are provided. NOTE 1 See ISO 18086 for the effects of alternating current on buried or immersed pipelines. Systems that can also be affected by stray currents include buried or immersed metal structures such as the following: a) pipeline systems; b) metal sheathed cables; c) tanks and vessels; d) earthing systems; e) steel reinforcement in concrete; f) sheet steel piling. This document gives guidelines for — the design of cathodic protection systems that might produce stray currents, — the design of pipeline systems, or elements of pipeline systems, which are buried or immersed, and which can be subject to stray current corrosion, and — the selection of appropriate protection or mitigation measures. Internal corrosion risks from stray currents are not dealt with in detail in this document but principles and measures described here can be applicable for minimizing the interference effects. NOTE 2 The impact of electromagnetic interference on above-ground appurtenances of pipeline systems is covered in EN 50443, IEC 61140, IEC 60364-4-41, IEC 60479-1, IEC 60364-5-52, IEC/TS 61201 and IEC/TR 60479-5. This document can also be used for pipeline systems outside of the petrochemical and natural gas industries and other buried or immersed structures. NOTE 3 EN 50162 provides guidance for railway related structures. The following editions for this book are also available...
About ISOISO, the International Organization for Standardization, brings global experts together to agree on the best way of doing things – for anything from making a product to managing a process. As one of the oldest non-governmental international organizations, ISO has enabled trade and cooperation between people and companies all over the world since 1946. The International Standards published by ISO serve to make lives easier, safer and better. |
GROUPS
|