BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of PD IEC/TS 62996:2017 2017This document addresses the safety assessments in the frequency range between 1 kHz and 6 MHz and provides limits for touch and touch currents for industrial installations or equipment for electroheating (EH) and electromagnetic processing of materials (EPM). Indirect contact by capacitive currents to parts of an earthed human body in an open space are also included, since the current is then distributed analogously in the part of the body and differs from cases of induced electric shock.
The overall safety requirements for the various types of EH or EPM equipment and installations in general result from the joint application of the general requirements specified in IEC 60519-1:2015 and related particular requirements covering specific types of installations or equipment. This document complements IEC 60519-1:2015.
On contacting, this document is based primarily on a movement of the primary contact area in relation to the live part, resulting in a contact or touch current. The awareness, perception and reaction times differ in comparison with a situation where a person is, for example, leaning towards or holding a conductor which subsequently becomes live, or a similar fault condition. Different considerations are then applicable and are dealt with in a detailed way in this document. Since high impedances for dry skin will result in the lowest touch current and the dryness is typically variable, data for only moist and wet skin are used in this document.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|