BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of BS EN ISO 3747:2010 20111.1 General This International Standard specifies a method for determining the sound power level or sound energy level of a noise source by comparing measured sound pressure levels emitted by a noise source (machinery or equipment) mounted in situ in a reverberant environment, with those from a calibrated reference sound source. The sound power level (or, in the case of noise bursts or transient noise emission, the sound energy level) produced by the noise source, in frequency bands of width one octave, is calculated using those measurements. The sound power level or sound energy level with frequency A-weighting applied is calculated using the octave-band levels. 1.2 Types of noise and noise sources The method specified in this International Standard is suitable for all types of noise (steady, non-steady, fluctuating, isolated bursts of sound energy, etc.) defined in ISO 12001. The method is primarily applicable to sources which emit broad-band noise. It can, however, also be used for sources which emit narrow-band noise or discrete tones, although there is a possibility that the measurement reproducibility is then degraded. The noise source under test can be a device, machine, component or sub-assembly, especially one which is non-movable. 1.3 Test environment The test environment that is applicable for measurements made in accordance with this International Standard is a room where the sound pressure level at the microphone positions depends mainly on reflections from the room surfaces (see 4.1). In measurements of ISO 12001:1996, accuracy grade 2 (engineering grade), background noise in the test environment is low compared to that of the noise source or reference sound source (see 4.2). 1.4 Measurement uncertainty Information is given on the uncertainty of the sound power levels and sound energy levels determined in accordance with this International Standard, for measurements made in octave bands and for A-weighted frequency calculations performed on them. The uncertainty conforms with that of either ISO 12001:1996, accuracy grade 2 (engineering grade) or ISO 12001:1996, accuracy grade 3 (survey grade), depending on the extent to which the requirements concerning the test environment are met.
About BSIBSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses. |
GROUPS
|