Cart (0)
  • No items in cart.
Total
$0
There is a technical issue about last added item. You can click "Report to us" button to let us know and we resolve the issue and return back to you or you can continue without last item via click to continue button.
Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(366)
(651)
(599)
(57)
(290)
(1055)
(738)
(2283)
(117)
(99009)
(58)
(650)
(137)
(42)
(29)
(20)
(102918)
(18)
(1)
(397)
(328)
(10763)
(7368)
(266)
(21)
(24376)
(1010)
(7)
(1737)
(26)
(19)
(28)
(4)
 
(6)
(7)
(128)
(1)
(4)
(58)
(5)
(7)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(27)
(7)
(8)
(20)
(1)
(3)
(50)
(7)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    BS EN IEC 60079-28:2026 Explosive atmospheres - Protection of equipment and transmission systems using optical radiation
    Edition: 2026
    $495.05
    / user per year

Description of BS EN IEC 60079-28:2026 2026

IEC 60079-28:2025 specifies additional requirements for Ex Equipment, Ex associated equipment or Ex Components containing optical systems emitting optical radiation, which is exposed to explosive atmospheres. These additional requirements are applicable for all equipment groups and all Equipment Protection Levels (EPL). This document contains requirements for optical radiation in the wavelength range from 380 nm to 10 µm. It covers the following ignition mechanisms: • Optical radiation is absorbed by surfaces or particles, causing them to heat up, and under certain circumstances this might allow them to attain a temperature which will ignite a surrounding explosive atmosphere. • In rare special cases, direct laser induced breakdown of the gas at the focus of a strong beam, producing plasma and a shock wave both eventually acting as ignition source. These processes can be supported by a solid material close to the breakdown point. • Annex A provides guidance when considering ignition mechanisms that influence the hazard of optics in explosive atmospheres. This document applies to a) laser equipment; and b) optical fibre equipment; and c) any optical system that converts light into convergent beams with focal points within the hazardous area only. This document does not apply to: d) laser equipment for EPL Mb, Gb, Gc, Db or Dc applications which complies with Class 1 limits in accordance with IEC 60825-1; or e) Single or multiple optical fibre cables not part of optical fibre equipment if the cables: 1) comply with the relevant industrial standards for optical fibre cables, along with additional protective means, for example robust cabling, conduit or raceway (for EPL Gb, Db, Mb, Gc or Dc); or 2) comply with the relevant industrial standards for optical fibre cables (for EPL Gc or Dc); or f) Optical radiation sources as defined in i) to iii) above where the optical radiation is fully contained in an enclosure complying with one of the following Types of Protection suitable for the EPL, or the minimum ingress protection rating specified: 1) flameproof "d" enclosures (IEC 60079-1); or 2) pressurized "p" enclosures (IEC 60079-2); or 3) restricted breathing "nR" enclosure (IEC 60079-15); or 4) dust protection "t" enclosures" (IEC 60079-31); or 5) an enclosure that provides a minimum ingress protection of IP 6X and where no internal absorbers are to be expected and complying with "Tests of enclosures" in IEC 60079-0. This document does not cover ignition by ultraviolet radiation and by absorption of the radiation in the explosive mixture itself. Explosive absorbers or absorbers that contain their own oxidizer as well as catalytic absorbers are also outside the scope of this document. This document supplements and modifies the general requirements of IEC 60079-0. Where a requirement of this document conflicts with a requirement of IEC 60079-0, the requirement of this document takes precedence. This third edition cancels and replaces the second edition published in 2015. This edition constitutes a technical revision



The following editions for this book are also available...

About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X