Search book title
Filters:
BOOKS
PACKAGES
EDITION
to
PUBLISHER
(1)
(353)
(641)
(599)
(58)
(290)
(1042)
(715)
(2249)
(117)
(97542)
(58)
(613)
(132)
(33)
(28)
(20)
(99791)
(18)
(1)
(396)
(328)
(7369)
(252)
(21)
(24907)
(849)
(7)
(1707)
(23)
(19)
(28)
(4)
 
(6)
(7)
(127)
(1)
(3)
(58)
(5)
(5)
(1)
(1)
(2)
(28)
(27)
(36)
(13)
(71)
(24)
(25)
(7)
(8)
(20)
(1)
(3)
(50)
(6)
(34)
CONTENT TYPE
 Act
 Admin Code
 Announcements
 Bill
 Book
 CADD File
 CAN
 CEU
 Charter
 Checklist
 City Code
 Code
 Commentary
 Comprehensive Plan
 Conference Paper
 County Code
 Course
 DHS Documents
 Document
 Errata
 Executive Regulation
 Federal Guideline
 Firm Content
 Guideline
 Handbook
 Interpretation
 Journal
 Land Use and Development
 Law
 Legislative Rule
 Local Amendment
 Local Code
 Local Document
 Local Regulation
 Local Standards
 Manual
 Model Code
 Model Standard
 Notice
 Ordinance
 Other
 Paperback
 PASS
 Periodicals
 PIN
 Plan
 Policy
 Product
 Product - Data Sheet
 Program
 Provisions
 Requirements
 Revisions
 Rules & Regulations
 Standards
 State Amendment
 State Code
 State Manual
 State Plan
 State Standards
 Statute
 Study Guide
 Supplement
 Sustainability
 Technical Bulletin
 All
  • BSI
    25/30507698 DC BS EN 18190 Precast concrete products - Performance assessment and declaration
    Edition: 2025
    $81.70
    / user per year

Description of 25/30507698 DC 2025

This document covers the following products regardless of if manufactured in factories or in temporary plants on site under the same conditions: a) Precast concrete products intended to be used as structural elements: - linear structural elements, including columns, beams and frame elements, made of concrete or lightweight concrete, reinforced or prestressed, including the use in contact with indoor air and the use in contact with soil or ground water, to the exclusion of products used as bridge elements and products of less than 4,5 m intended to be used as lintels in masonry wall; - beams made of concrete or lightweight concrete, reinforced or prestressed, with or without clay shells, to be used in conjunction with blocks as beam-and-block system and intended to be used for floor and roofing systems, including the use in contact with indoor air and the use in contact with soil or ground water; - foundation elements, including columns with integrated foundation elements, pocket foundation elements and sockets, made of reinforced concrete or lightweight concrete, including the use in contact with soil or ground water, to the exclusion of products using prestressing steel; - foundation piles and segments of piles made of concrete or lightweight concrete, reinforced or prestressed, including the use in contact with soil or ground water; - poles (also called masts), made of concrete or lightweight concrete, hollow or solid, reinforced or prestressed, in one piece or composed of elements and their inserts and connectors, including the use in contact with soil or ground water, to the exclusion of lighting columns for use in traffic circulation areas; - bridge deck elements made of concrete, reinforced or prestressed, including the use in contact with soil or ground water, to the exclusion of abutments, barriers, bumpers, piers, guards and arches; - floor plates made of concrete or lightweight concrete, reinforced or prestressed, intended to be used in floor systems in conjunction with cast-in-situ concrete, including the use in contact with indoor air and the use in contact with soil or ground water, to the exclusion of products used as bridge elements, and products with stiffening ribs taking a major part of the mechanical resistance, considered either as ribbed floor elements or hollow-core slabs; - solid slabs made of concrete or lightweight concrete, reinforced or prestressed, without voids or void formers intended to be used as self-supporting structural elements, such as floors, roofs, landings and balconies, which can be installed without a structural topping but to which a structural topping can be added, and with a cross section which is rectangular but may present slopes for drainage, grooves for handling and shear keys, including the use in contact with indoor air and the use in contact with soil or ground water, to the exclusion of balustrades without structural behaviour and slabs manufactured using hollow core slabs manufacturing process; - hollow core slabs and solid slabs manufactured in the same way but without hollow cores, made of concrete or lightweight concrete, reinforced or prestressed, with a maximum depth of 500 mm for prestressed elements and 300 mm for reinforced elements, to be used in conjunction with cast-in-situ concrete or without it, including the use in contact with indoor air and the use in contact with soil or ground water; - ribbed floor elements made of concrete or lightweight concrete, reinforced or prestressed, intended to be used for floors and roofs, including the use in contact with indoor air and the use in contact with soil or ground water, to the exclusion of floor plates for floor systems; (...)



About BSI

BSI Group, also known as the British Standards Institution is the national standards body of the United Kingdom. BSI produces technical standards on a wide range of products and services and also supplies certification and standards-related services to businesses.

X