BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Description of ASTM-F2903 2011ASTM F2903 - 11Standard Guide for Tissue Engineered Medical Products (TEMPs) for Reinforcement of Tendon and Ligament Surgical RepairActive Standard ASTM F2903 | Developed by Subcommittee: F04.44 Book of Standards Volume: 13.02 ASTM F2903Significance and Use Injuries to tendons or ligaments are frequently treated by surgery to repair the damaged tissues and facilitate the healing process. The potential of TEMPs to enhance the outcomes (including function, pain, anatomy) of the surgical repair has been recognized. Examples of tissues that when injured may be appropriate for repair using TEMPs: rotator cuff with a partial or full tear; Achilles tendon; Achilles tendon after harvesting for anterior cruciate ligament repair; patella tendon; patella tendon after harvesting for anterior cruciate ligament repair; quadriceps tendon; posterior cruciate ligament; medial collateral ligaments; lateral collateral ligaments; flexor tendons. TEMPs may be used with the intent to improve the surgical outcome of tendon or ligament repair by (a) assuming some of the mechanical load experienced at the repair site to stabilize the surgical repair, (b) improving the natural biological healing process, or (c) a combination of these mechanisms. TEMPs should improve clinical outcome. This may be accomplished by reducing or eliminating pain, returning function, shortening the recovery time following surgery, facilitating early mobility, improving return of strength, improving mobility, or other clinically relevant parameters. The mechanism used by TEMPs to improve surgical repair should be understood and this conclusion should be supported by experimental results and should be supportive of the primary function of the TEMP. TEMPs with the primary function of mechanical reinforcement may also have a secondary, biological function. When the product is used to improve the body s natural biological repair process of tendons or ligaments, the product should allow cell attachment, migration, infiltration, extracellular matrix deposition and organization, formation of tendon or ligament repair tissue, integration with adjacent tendon, ligament or bone, tendon-bone attachment, or more than one of these actions. When the TEMP is used to provide a mechanical support of the surgical repair of a tendon or ligament, the product may provide enhanced mechanical properties of the repaired construct immediately after the surgery. Ideally, TEMPs would have mechanical properties similar to the uninjured native tissue being repaired. After surgery, the TEMP should limit the amount of tendon/ligament separation from the bone, or separation of the fractured ends of the tendon or ligament, or reduce the number of patients that have these as outcomes of the surgery. The TEMP may allow functionality to return to the repaired tendon or ligament in a shorter time than without the use of the product. 1. Scope 1.1 This guide is intended as a resource for individuals and organizations involved in the development, production, and delivery of tissue engineered medical products (TEMPs) intended to provide a mechanical (functional) reinforcement of the surgical repair of tendons and ligaments. 1.2 Surgical repair can include procedures that repair tendon to tendon, tendon to bone, tendon to muscle, ligament to ligament, and ligament to bone. In the context of this guide, a tendon is a fibrous cord or band that connects a muscle to a bone or other structure and consists of both dense collagenous fibers and rows of elongated tendon cells. In contrast, a ligament is a band or sheet of fibrous tissue connecting two or more bones, or cartilagenous structures. 1.3 Examples of TEMPs for use in reinforcement of tendon or ligament repairs include extracellular matrices (including allograft tissue, xenograft tissue, and tissue engineered extracellular matrix), polymeric matrices, membranes, or combinations of two or more of these, with or without cells and/or molecular mediators, where the function is to reinforce the surgical repair of tendon to tendon, tendon to bone, tendon to muscle, ligament to ligament, or ligament to bone. 1.4 The products may be rapidly degrading, slowly degrading, or non-degrading. 1.5 The guide is not intended to apply to TEMPs that have a primary function to induce a biological repair through cell or molecular action, although biologic activity may be a feature of the TEMPs. Examples of products or product concepts that are not included are (a) growth factors or cytokines applied to a biologic or synthetic scaffold, and (b) platelet-enriched plasma applied to or within a biologic or polymeric scaffold, where the primary function of the product is biologic. 1.6 The guide is not intended to apply to TEMPs that have a primary function to induce a chemical repair. An example of a product or product concept that would not be included would be a polymeric matrix containing reagents that glue collagenous tissues together. 1.7 The guide is not intended to apply to TEMPs that are designed to be used to achieve primary surgical repair of injured tendons and ligaments. 1.8 The guide is not intended to apply to TEMPs that are designed to replace tendons or ligaments. 1.9 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard. 1.10 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
ASTM Standards D1004 Test Method for Tear Resistance (Graves Tear) of Plastic Film and Sheeting D2990 Test Methods for Tensile, Compressive, and Flexural Creep and Creep-Rupture of Plastics D3786 Test Method for Bursting Strength of Textile Fabrics--Diaphragm Bursting Strength Tester Method D3787 Test Method for Bursting Strength of Textiles--Constant-Rate-of-Traverse (CRT) Ball Burst Test D5035 Test Method for Breaking Force and Elongation of Textile Fabrics (Strip Method) E139 Test Methods for Conducting Creep, Creep-Rupture, and Stress-Rupture Tests of Metallic Materials F1635 Test Method for in vitro Degradation Testing of Hydrolytically Degradable Polymer Resins and Fabricated Forms for Surgical Implants F1978 Test Method for Measuring Abrasion Resistance of Metallic Thermal Spray Coatings by Using the Taber Abraser F2150 Guide for Characterization and Testing of Biomaterial Scaffolds Used in Tissue-Engineered Medical Products F2210 Guide for Processing Cells, Tissues, and Organs for Use in Tissue Engineered Medical Products F2211 Classification for Tissue Engineered Medical Products (TEMPs) F2212 Guide for Characterization of Type I Collagen as Starting Material for Surgical Implants and Substrates for Tissue Engineered Medical Products (TEMPs) F2312 Terminology Relating to Tissue Engineered Medical Products F2383 Guide for Assessment of Adventitious Agents in Tissue Engineered Medical Products (TEMPs) F2739 Guide for Quantitating Cell Viability Within Biomaterial Scaffolds ISO Documents ISO224421 Medical Devices Utilizing Animal Tissues and their DerivativesPart 1: Application of Risk ManagementU.S. Regulations 21CFR1271 Human Cells, Tissues, and Cellular and Tissue-Based ProductsICH Document Q1A(R2) Stability Testing of New Drug Substances and ProductsKeywords Achilles; bone anchors; ligament; quadriceps; reinforcement; repair; rotator cuff; sutures; tendon; ICS Code ICS Number Code 11.100.99 (Other standards related to laboratory medicine) DOI: 10.1520/F2903-11 ASTM International is a member of CrossRef. ASTM F2903This book also exists in the following packages...Subscription InformationMADCAD.com ASTM Standards subscriptions are annual and access is unlimited concurrency based (number of people that can access the subscription at any given time) from single office location. For pricing on multiple office location ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
Some features of MADCAD.com ASTM Standards Subscriptions are: - Immediate Access: As soon as the transaction is completed, your ASTM Standards Subscription will be ready for access.
For any further information on MADCAD.com ASTM Standards Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASTMASTM International, formerly known as the American Society for Testing and Materials (ASTM), is a globally recognized leader in the development and delivery of international voluntary consensus standards. Today, some 12,000 ASTM standards are used around the world to improve product quality, enhance safety, facilitate market access and trade, and build consumer confidence. ASTM’s leadership in international standards development is driven by the contributions of its members: more than 30,000 of the world’s top technical experts and business professionals representing 150 countries. Working in an open and transparent process and using ASTM’s advanced electronic infrastructure, ASTM members deliver the test methods, specifications, guides, and practices that support industries and governments worldwide. |
GROUPS
|