ASTM E2007-00(2006)
Historical Standard: ASTM E2007-00(2006) Standard Guide for Computed Radiology (Photostimulable Luminescence (PSL) Method)
SUPERSEDED (see Active link, below)
ASTM E2007
1. Scope
1.1 This guide covers practices and image quality measuring systems for the detection, display, and recording of CR data files. These data files, used in materials examination, are generated by penetrating radiation passing through the subject material and producing an image via a storage phosphor imaging plate. Although the described radiation sources are specifically X-ray and gamma-ray, the general concepts can be used for other radiation sources such as neutrons. The image detection and display techniques are nonfilm, but the use of a hard copy as a means for permanent recording of the image is not precluded.
1.2 This guide is for tutorial purposes only. It outlines the general principles of computed radiology (CR) imaging in which luminescence is emitted by a storage phosphor imaging plate, by means of photo stimulation after the detector has been penetrated by x-rays or gamma radiation.
1.3 The values stated in SI units are to be regarded as the standard. The inch-pound units given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific safety precautionary statements, see Section 7.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
E94 Guide for Radiographic Examination
E746 Practice for Determining Relative Image Quality Response of Industrial Radiographic Imaging Systems
E747 Practice for Design, Manufacture and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology
E1025 Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI) Used for Radiology
E1316 Terminology for Nondestructive Examinations
E1453 Guide for Storage of Magnetic Tape Media that Contains Analog or Digital Radioscopic Data
E2002 Practice for Determining Total Image Unsharpness in Radiology
E2033 Practice for Computed Radiology (Photostimulable Luminescence Method)
E2339 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)
E2422 Digital Reference Images for Inspection of Aluminum Castings
E2445 Practice for Qualification and Long-Term Stability of Computed Radiology Systems
E2446 Practice for Classification of Computed Radiology Systems
E2660 Digital Reference Images for Investment Steel Castings for Aerospace Applications
E2669 Digital Reference Images for Titanium Castings
SMPTE Standard
RP-133 Specifications for Medical Diagnostic Imaging Test Pattern for Television Monitors and Hard-Copy Recording Cameras Available from Society of Motion Picture and Television Engineers (SMPTE), 3 Barker Ave, 5th Floor, White Plains, NY 10601.Keywords
computed; contrast; digital; image plate; media; monitor; noise; pixel; radiography; resolution; scanner; Calibration--nondestructive analysis instrumentation; Configuration; CR (computed radiology) imaging systems; Electronic devices/instruments/equipment; Nondestructive evaluation (NDE); PSL (photostimulable luminescence) method; Radiological examination; Radioluminescence;
ICS Code
ICS Number Code 17.180.01 (Optics and optical measurement in general)
DOI: 10.1520/E2007-00R06