ASTM E1998-99
Historical Standard: ASTM E1998-99 Standard Guide for Assessing Depressurization-Induced Backdrafting and Spillage from Vented Combustion Appliances
SUPERSEDED (see Active link, below)
ASTM E1998
1. Scope
1.1 This guide describes and compares different methods for assessing the potential for, or existence of, depressurization-induced backdrafting and spillage from vented residential combustion appliances.
1.2 Assessment of depressurization-induced backdrafting and spillage is conducted under either induced depressurization or natural conditions.
1.3 Residential vented combustion appliances addressed in this guide include hot water heaters and furnace. This guide also is applicable to boilers.
1.4 The methods given in this guide are applicable to Category I (draft-hood and induced-fan equipped) furnaces. The guide does not apply to Category III (power-vent equipped) or Category IV (direct-vent) furnaces.
1.5 The methods in this guide are not intended to identify backdrafting or spillage due to vent blockage or heat-exchanger leakage.
1.6 This guide is not intended to provide a basis for determining compliance with code requirements on appliance and venting installation, but does include a visual assessment of the installation. This assessment may indicate the need for thorough inspection by a qualified technician.
1.7 Users of the methods in this guide should be familiar with combustion appliance operation and with making house-tightness measurements using a blower door. Some methods described in this guide require familiarity with differential-pressure measurements and use of computer-based data-logging equipment.
1.8 This guide does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Carbon monoxide (CO) exposure or flame roll-out may occur when performing certain procedures given in this guide. See Section 7, for precautions that must be taken in conducting such procedures.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
E631 Terminology of Building Constructions
E779 Test Method for Determining Air Leakage Rate by Fan Pressurization
CAN/CGSB Standards
CAN/CGSB51.71 The Spillage Test--Method to Determine the Potential for Pressure-Induced Spillage from Vented, Fuel-Fired; Space Heating Appliances; Water Heaters, and FireplacesANSI Standards
ANSIZ21.47 Gas-fired Central FurnaceNFPA Standards
NFPA54 National Fuel Gas CodeKeywords
backdrafting; carbon dioxide; carbon monoxide; combustion appliances; downdrafting; draft diverter; draft hood; flue gas; house depressurization; house tightness; induced fan; nitrogen oxides; residences; spillage; water vapor: Carbon dioxide; Carbon monoxide (CO); Backdrafting; Combustion appliances; Depressurization; Downdrafting; Flue gas; House depressurization test; Nitrogen oxides; Residential depressurization/tightness; Residential dwellings; Spillage; Vented combustion appliances; Water vapor ;
ICS Code
ICS Number Code 91.140.65 (Water heating equipment)
DOI: 10.1520/E1998-99
ASTM International is a member of CrossRef.