ASTM E1560-95(2001)
Historical Standard: ASTM E1560-95(2001) Standard Test Method for Gravimetric Determination of Nonvolatile Residue From Cleanroom Wipers
SUPERSEDED (see Active link, below)
ASTM E1560
1. Scope
1.1 This test method covers the determination of solvent extractable nonvolatile residue (NVR) from wipers used in assembly, cleaning, or testing of spacecraft, but not from those used for analytical surface sampling of hardware.
1.2 The values stated in SI units are to be regarded as the standard. No other units of measurement are included in this standard.
1.3 The NVR of interest is that which can be extracted from cleanroom wipers using a specified solvent that has been selected for its extractive qualities. Alternative solvents may be selected, but since their use may result in different values being generated, they must be identified in the procedure data sheet.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1193 Specification for Reagent Water
E2217 Practice for Design and Construction of Aerospace Cleanrooms and Contamination Controlled Areas
F24 Test Method for Measuring and Counting Particulate Contamination on Surfaces
F50 Practice for Continuous Sizing and Counting of Airborne Particles in Dust-Controlled Areas and Clean Rooms Using Instruments Capable of Detecting Single Sub-Micrometre and Larger Particles
Military Standards
MIL-STD-1916 Acceptance on Zero Sampling InspectionOther Documents
ISO14644-2 Cleanrooms and Associated Controlled Environments, Specifications for testing and monitoring to prove continued compliance with ISO 14644-1 ,Keywords
cleanroom wipers; non-volatile residue; NVR; wipers; Cleanrooms (materials/applications); Residue; Nonvolatile residue (NVR); Solvent-extractable substances; Spacecraft materials; Wipers/wipes
ICS Code
ICS Number Code 49.025.99 (Other materials); 71.040.50 (Physicochemical methods of analysis)
DOI: 10.1520/E1560-95R01