ASTM D3162-94(2005)
Historical Standard: ASTM D3162-94(2005) Standard Test Method for Carbon Monoxide in the Atmosphere (Continuous Measurement by Nondispersive Infrared Spectrometry)
SUPERSEDED (see Active link, below)
ASTM D3162
1. Scope
1.1 This test method is applicable to the determination of the carbon monoxide (CO) concentration of the atmosphere between 0.6 mg/m 3 (0.5 ppm(v)) and 115 mg/m 3 (100 ppm(v)). The measuring principle is based on the absorption of infrared radiation by CO in the 4.7 m region (1) .
1.2 The test method has a limit of detection of about 0.6 mg/m 3 (0.5 ppm(v)) carbon monoxide in air.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section for additional precautions.
2. Referenced Documents (purchase separately) The documents listed below are referenced within the subject standard but are not provided as part of the standard.
ASTM Standards
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D1357 Practice for Planning the Sampling of the Ambient Atmosphere
D1914 Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
D3249 Practice for General Ambient Air Analyzer Procedures
D3631 Test Methods for Measuring Surface Atmospheric Pressure
E1 Specification for ASTM Liquid-in-Glass Thermometers
E180 Practice for Determining the Precision of ASTM Methods for Analysis and Testing of Industrial and Specialty Chemicals
Keywords
ambient atmospheres; analysis; carbon monoxide; nondispersive infrared spectroscopy; sampling; Air monitoring; Ambient air/atmospheric analysis; Atmospheric analysis; Automated procedures--atmospheric analysis; Calibration--air/atmospheric analysis instruments; Carbon monoxide (CO); Continuous measurement/monitoring--atmospheric analysis; Infrared (IR) analysis; Infrared spectrometry; Minimum performance specifications; Nondispersive infrared analysis; Operational conditions/objectives/principals; Replacement span gas cylinder
ICS Code
ICS Number Code 13.040.20 (Ambient atmospheres)