BOOKS
PACKAGES
EDITION
PUBLISHER
CONTENT TYPE
Act
Admin Code
Announcements
Bill
Book
CADD File
CAN
CEU
Charter
Checklist
City Code
Code
Commentary
Comprehensive Plan
Conference Paper
County Code
Course
DHS Documents
Document
Errata
Executive Regulation
Federal Guideline
Firm Content
Guideline
Handbook
Interpretation
Journal
Land Use and Development
Law
Legislative Rule
Local Amendment
Local Code
Local Document
Local Regulation
Local Standards
Manual
Model Code
Model Standard
Notice
Ordinance
Other
Paperback
PASS
Periodicals
PIN
Plan
Policy
Product
Product - Data Sheet
Program
Provisions
Requirements
Revisions
Rules & Regulations
Standards
State Amendment
State Code
State Manual
State Plan
State Standards
Statute
Study Guide
Supplement
Sustainability
Technical Bulletin
All
|
Content DescriptionASHRAE Guideline 36 establishes standardized advanced sequences of operation for common HVAC systems that help to reduce engineering, programming, and commissioning time; reduce energy consumption; and improve indoor air quality. Rather than develop sequences themselves, design engineers can adapt existing standard sequences that have been proven to perform. Energy consumption is reduced by making systems less dependent on proper implementation and commissioning of control sequences, and by ensuring that proven, cost-effective strategies, including those required by ASHRAE standards and building codes, are fully implemented. IAQ is improved by ensuring control sequences are in compliance with IAQ standards and codes such as ASHRAE Standard 62.1. Diagnostic software detects and diagnoses system faults and makes operators aware of them before they cause performance problems, further reducing energy consumption and reducing system down time. The 2024 edition of ASHRAE Guideline 36 includes 23 addenda to the 2021 edition. Key updates include: Addition of three new modular zone-humidity-limiting/dehumidification strategies for multiple-zone VAV air-handling units (AHU), where the AHU supply air temperature set point is reset to limit zone humidity. The designer may elect to incorporate one, two, or all of the strategies. Addition of an outdoor air pollution mode used to manually or automatically disable airside economizers when outdoor air contaminants exceed user-defined thresholds Enhanced sequences to existing sections that, for example, provide flexibility to establish different demand limit adjustments for different zone types, define zone group Bug fixes to existing sections Guideline 36 is intended for HVAC designers, control contractors, commissioning agents, and building owners, operators, and maintenance technicians.Subscription InformationMADCAD.com ASHRAE subscriptions are annual and access is concurrency based (number of people that can access the subscription at any given time).
Some features of MADCAD.com ASHRAE Subscriptions are:
- Floating concurrency model: Set your concurrency level and share your ASHRAE Subscriptions among your offices enterprise-wide.
- Immediate Access: As soon as the transaction is completed, your ASHRAE Subscription will be ready for access.
For any further information on MADCAD.com ASHRAE Subscriptions, please contact us at info@madcad.com or +1 800.798.9296.
About ASHRAEASHRAE, founded in 1894, is a building technology society with more than 50,000 members worldwide. The Society and its members focus on building systems, energy efficiency, indoor air quality and sustainability within the industry. Through research, standards writing, publishing and continuing education, ASHRAE shapes tomorrow’s built environment today.
ASHRAE was formed as the American Society of Heating, Refrigerating and Air-Conditioning Engineers by the merger in 1959 of American Society of Heating and Air-Conditioning Engineers (ASHAE) founded in 1894 and The American Society of Refrigerating Engineers (ASRE) founded in 1904.
|