Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

NEMA BI 50009-2024 Low Voltage Cartridge Fuses, 2024
- NEMA BI 50009-2024 [Go to Page]
- National Electrical Manufacturers Association
- Section 1 GENERAL [Go to Page]
- 1.1 Scope
- 2.1 Definitions
- Section 3 SERVICE CONDITIONS [Go to Page]
- 3.1 Usual Service Conditions
- 3.2 Unusual Service Conditions
- Section 4 RATINGS [Go to Page]
- 4.1 Current Ratings of Non-Time-Delay Fuses [Go to Page]
- Table 4-1
- Current Ratings of Non-Time-Delay Fuses
- 4.2 Current Ratings of Time-Delay Fuses [Go to Page]
- Table 4-2
- Current Ratings of Time-Delay Fuses
- 4.3 AC Voltage Ratings [Go to Page]
- Table 4-3
- AC Voltage Ratings—Time-Delay and Non-Time-Delay Fuses
- 4.4 DC Voltage Ratings [Go to Page]
- Table 4-4
- DC Voltage Ratings—Time-Delay and Non-Time-Delay Fuses
- 4.5 AC Interrupting Ratings [Go to Page]
- Table 4-5
- AC Interrupting Ratings—Time-Delay and Non-Time-Delay Fuses
- 4.6 DC Interrupting Ratings [Go to Page]
- Table 4-6
- DC Interrupting Ratings—Time-Delay and Non-Time-Delay Fuses
- 4.7 Frequency Rating
- Section 5 FUSE CLASSES [Go to Page]
- 5.1 Summary of Fuse Classes
- 5.2 Class G Fuses (Current Limiting) 0–60 Amperes, 480 V and 600 V, Alternating Current
- 5.3 Class H Fuses 0–600 Amperes, 250 V and 600 V, Alternating Current
- 5.4 Class J Fuses (Current Limiting) 0–600 Amperes, 600 V, Alternating Current
- 5.5 Class K Fuses 0–600 Amperes, 250 V and 600 V, Alternating Current
- 5.6 Class L Fuses (Current Limiting) 100–6000 Amperes, 600 V, Alternating Current
- 5.7 Class R Fuses (Current Limiting) 0–600 Amperes, 250 V and 600 V, Alternating Current
- 5.8 Class T Fuses (Current Limiting) 0–1200 Amperes, 300 V and 600 V Alternating Current
- 5.9 Class CC Fuses (Current Limiting) 0–30 Amperes, 600 V, Alternating Current
- 5.10 Class C Fuses (Current Limiting) 0–1200 Amperes, 600 V, Alternating Current
- 5.11 Class CA (Current Limiting) 0–30 Amperes, 600 V, Alternating Current
- 5.12 Class CB (Current Limiting) 0–60 Amperes, 600 V, Alternating Current
- 5.13 Fuses for Photovoltaic Systems PV Fuses [Go to Page]
- Table 5-1
- Summary of Fuse Classes and Alternating Current Ratings*
- Table 5-2
- Dimensions of Class G Fuses, mm (in.)
- Table 5-3
- Dimensionsa of Class H and K Fuses, mm (in.)
- Table 5-4
- Dimensionsa of Class J Fuses, mm (in.)
- Table 5-5
- Dimensionsa of Class L Fuses, mm (in.)
- Table 5-6
- Dimensionsa of Ferrule Type Class R Fuses, mm (in.)
- Table 5-7
- Dimensionsa of Knife Blade Type Class R Fuses, mm (in.)
- Table 5-8
- Dimensionsa of Ferrule Type Class T Fuses, mm (in.)
- Table 5-9
- Dimensionsa of Knife Blade Type T Fuses, mm (in.)
- Table 5-10
- Dimensionsa of Class CC Fuses, mm (in.)
- Table 5-11
- Dimensions of Class C Fuses, mm (in.)
- Table 5-12
- Dimensions of Class CA Fuses, mm (in.)
- Table 5-13
- Dimensions of Class CB Fuses, mm (in.)
- Section 6 PERFORMANCE [Go to Page]
- 6.1 General
- 6.2 Current Carrying Capacity and Temperature Rise Tests [Go to Page]
- Table 6-1
- Maximum Temperature Rises
- (Classes C, H, J, K, R, and T Fuses)
- Table 6-2
- Maximum Temperature Rises
- (Classes CA, CB, CC, and G Fuses)
- Table 6-3
- Test Conductor Size
- Table 6-4
- Bus Bar Cross-Section and Shorting Bar Temperature Rises
- 6.3 Overload Opening Time [Go to Page]
- Table 6-5
- Classes CA, CB, CC, and G Fuses
- Table 6-6
- Overload Opening Time
- Classes H, J, K, L, R, and T Fuses
- 6.4 Interrupting Tests at Rated Voltage [Go to Page]
- Table 6-7
- Test Levels for High Interrupting Rating Fuses (Above 10 kA)
- Table 6-8
- Class CC Fuses (600 V)
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-9
- Class G Fuses
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-10
- Class J Fuses (600 V)Maximum Peak Let-Through Current Ip (Amperes)
- and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-11A
- Class K Fuses (250 & 600 V)
- Maximum Peak Let-Through Current Ip (Amperes)
- and Clearing I2t
- (Amperes Squared Seconds) at 50 and 100 kA
- Table 6-11B
- Class K Fuses (250 & 600 V)
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds) at 200 kA
- Table 6-12
- Class RK1 Fuses (250 & 600 V)
- Maximum Peak Let-Through Current Ip (A) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-13
- Class RK5 Fuses (250 & 600 V)
- Maximum Peak Let-Through Current Ip (Amperes)
- and Clearing I2t (Amperes Squared Seconds)
- Table 6-14
- Class L Fuses (600 V)
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-15
- Class T Fuses (300 V)
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-16
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-17
- Maximum Peak Let-Through Current Ip (Amperes)and Clearing I2t
- (Amperes Squared Seconds)
- Table 6-18
- Class CA and Class CB Fuses
- Maximum Peak Let-Through Current Ip (Amperes) and Clearing I2t
- (Amperes Squared Seconds)
- 6.5 Maximum Energy
- 6.6 Maximum Threshold Ratio [Go to Page]
- Table 6-19
- Maximum Threshold Ratios
- 6.7 Direct Current Tests for Industrial Fuses [Go to Page]
- Table 6-20
- Maximum Time Constants
- 6.8 Direct Current Tests for Photovoltaic Fuses [Go to Page]