BS EN 60204-1:2018+A1:2025 Safety of machinery. Electrical equipment of machines - General requirements, 2025
- undefined
- CONTENTS
- FOREWORD
- INTRODUCTION
- Figures [Go to Page]
- Figure 1 – Block diagram of a typical machine
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviated terms [Go to Page]
- 3.1 Terms and definitions
- 3.2 Abbreviated terms
- 4 General requirements [Go to Page]
- 4.1 General
- 4.2 Selection of equipment [Go to Page]
- 4.2.1 General
- 4.2.2 Switchgear
- 4.3 Electrical supply [Go to Page]
- 4.3.1 General
- 4.3.2 AC supplies
- 4.3.3 DC supplies
- 4.3.4 Special supply systems
- 4.4 Physical environment and operating conditions [Go to Page]
- 4.4.1 General
- 4.4.2 Electromagnetic compatibility (EMC)
- 4.4.3 Ambient air temperature
- 4.4.4 Humidity
- 4.4.5 Altitude
- 4.4.6 Contaminants
- 4.4.7 Ionizing and non-ionizing radiation
- 4.4.8 Vibration, shock, and bump
- 4.5 Transportation and storage
- 4.6 Provisions for handling
- 5 Incoming supply conductor terminations and devices for disconnecting and switching off [Go to Page]
- 5.1 Incoming supply conductor terminations
- 5.2 Terminal for connection of the external protective conductor
- 5.3 Supply disconnecting (isolating) device [Go to Page]
- 5.3.1 General
- 5.3.2 Type
- Tables [Go to Page]
- Table 1 – Minimum cross-sectional area of copper protective conductors [Go to Page]
- 5.3.3 Requirements
- 5.3.4 Operating means of the supply disconnecting device
- 5.3.5 Excepted circuits
- Figure 2 – Disconnector isolator
- Figure 3 – Disconnecting circuit breaker
- 5.4 Devices for removal of power for prevention of unexpected start-up
- 5.5 Devices for isolating electrical equipment
- 5.6 Protection against unauthorized, inadvertent and/or mistaken connection
- 6 Protection against electric shock [Go to Page]
- 6.1 General
- 6.2 Basic protection [Go to Page]
- 6.2.1 General
- 6.2.2 Protection by enclosures
- 6.2.3 Protection by insulation of live parts
- 6.2.4 Protection against residual voltages
- 6.2.5 Protection by barriers
- 6.2.6 Protection by placing out of reach or protection by obstacles
- 6.3 Fault protection [Go to Page]
- 6.3.1 General
- 6.3.2 Prevention of the occurrence of a touch voltage
- 6.3.3 Protection by automatic disconnection of supply
- 6.4 Protection by the use of PELV [Go to Page]
- 6.4.1 General requirements
- 6.4.2 Sources for PELV
- 7 Protection of equipment [Go to Page]
- 7.1 General
- 7.2 Overcurrent protection [Go to Page]
- 7.2.1 General
- 7.2.2 Supply conductors
- 7.2.3 Power circuits
- 7.2.4 Control circuits
- 7.2.5 Socket outlets and their associated conductors
- 7.2.6 Lighting circuits
- 7.2.7 Transformers
- 7.2.8 Location of overcurrent protective devices
- 7.2.9 Overcurrent protective devices
- 7.2.10 Rating and setting of overcurrent protective devices
- 7.3 Protection of motors against overheating [Go to Page]
- 7.3.1 General
- 7.3.2 Overload protection
- 7.3.3 Over-temperature protection
- 7.4 Protection against abnormal temperature
- 7.5 Protection against the effects of supply interruption or voltage reduction and subsequent restoration
- 7.6 Motor overspeed protection
- 7.7 Additional earth fault/residual current protection
- 7.8 Phase sequence protection
- 7.9 Protection against overvoltages due to lightning and to switching surges
- 7.10 Short-circuit current rating
- 8 Equipotential bonding [Go to Page]
- 8.1 General
- Figure 4 – Example of equipotential bonding for electrical equipment of a machine
- 8.2 Protective bonding circuit [Go to Page]
- 8.2.1 General
- 8.2.2 Protective conductors
- 8.2.3 Continuity of the protective bonding circuit
- 8.2.4 Protective conductor connecting points
- 8.2.5 Mobile machines
- 8.2.6 Additional requirements for electrical equipment having earth leakage currents higher than 10 mA
- Figure 5 – Symbol IEC 60417-5019: Protective earth
- 8.3 Measures to restrict the effects of high leakage current
- 8.4 Functional bonding
- 9 Control circuits and control functions [Go to Page]
- 9.1 Control circuits [Go to Page]
- 9.1.1 Control circuit supply
- Figure 6 – Symbol IEC 60417-5020: Frame or chassis [Go to Page]
- 9.1.2 Control circuit voltages
- 9.1.3 Protection
- 9.2 Control functions [Go to Page]
- 9.2.1 General
- 9.2.2 Categories of stop functions
- 9.2.3 Operation
- 9.2.4 Cableless control system (CCS)
- 9.3 Protective interlocks [Go to Page]
- 9.3.1 Reclosing or resetting of an interlocking safeguard
- 9.3.2 Exceeding operating limits
- 9.3.3 Operation of auxiliary functions
- 9.3.4 Interlocks between different operations and for contrary motions
- 9.3.5 Reverse current braking
- 9.3.6 Suspension of safety functions and/or protective measures
- 9.4 Control functions in the event of failure [Go to Page]
- 9.4.1 General requirements
- 9.4.2 Measures to minimize risk in the event of failure
- 9.4.3 Protection against malfunction of control circuits
- Figure 7 – Method a) Earthed control circuit fed by a transformer
- Figure 8 – Method b1) Non-earthed control circuit fed by transformer
- Figure 9 – Method b2) Non-earthed control circuit fed by transformer
- Figure 10 – Method b3) Non-earthed control circuit fed by transformer
- Figure 11 – Method c) Control circuits fed by transformerwith an earthed centre-tap winding
- Figure 12 – Method d1a) Control circuit without transformer connected between a phase and the neutral of an earthed supply system
- Figure 13 – Method d1b) Control circuit without transformer connected between two phases of an earthed supply system
- Figure 14 – Method d2a) Control circuit without transformer connected between phase and neutral of a non-earthed supply system
- Figure 15 – Method d2b) control circuit without transformer connected between two phases of a non-earthed supply system
- 10 Operator interface and machine-mounted control devices [Go to Page]
- 10.1 General [Go to Page]
- 10.1.1 General requirements
- 10.1.2 Location and mounting
- 10.1.3 Protection
- 10.1.4 Position sensors
- 10.1.5 Portable and pendant control stations
- 10.2 Actuators [Go to Page]
- 10.2.1 Colours
- 10.2.2 Markings
- 10.3 Indicator lights and displays [Go to Page]
- 10.3.1 General
- 10.3.2 Colours
- Table 2 – Symbols for actuators (Power)
- Table 3 – Symbols for actuators (Machine operation) [Go to Page]
- 10.3.3 Flashing lights and displays
- 10.4 Illuminated push-buttons
- 10.5 Rotary control devices
- 10.6 Start devices
- Table 4 – Colours for indicator lights and their meanings with respect to the condition of the machine
- 10.7 Emergency stop devices [Go to Page]
- 10.7.1 Location of emergency stop devices
- 10.7.2 Types of emergency stop device
- 10.7.3 Operation of the supply disconnecting device to effect emergency stop
- 10.8 Emergency switching off devices [Go to Page]
- 10.8.1 Location of emergency switching off devices
- 10.8.2 Types of emergency switching off device
- 10.8.3 Local operation of the supply disconnecting device to effect emergency switching off
- 10.9 Enabling control device
- 11 Controlgear: location, mounting, and enclosures [Go to Page]
- 11.1 General requirements
- 11.2 Location and mounting [Go to Page]
- 11.2.1 Accessibility and maintenance
- 11.2.2 Physical separation or grouping
- 11.2.3 Heating effects
- 11.3 Degrees of protection
- 11.4 Enclosures, doors and openings
- 11.5 Access to electrical equipment
- 12 Conductors and cables [Go to Page]
- 12.1 General requirements
- 12.2 Conductors
- 12.3 Insulation
- 12.4 Current-carrying capacity in normal service
- Table 5 – Minimum cross-sectional areas of copper conductors
- 12.5 Conductor and cable voltage drop
- Table 6 – Examples of current-carrying capacity (Iz) of PVC insulated copper conductors or cables under steady-state conditions in an ambient air temperature of +40 °C for different methods of installation
- 12.6 Flexible cables [Go to Page]
- 12.6.1 General
- 12.6.2 Mechanical rating
- 12.6.3 Current-carrying capacity of cables wound on drums
- 12.7 Conductor wires, conductor bars and slip-ring assemblies [Go to Page]
- 12.7.1 Basic protection
- 12.7.2 Protective conductors
- 12.7.3 Protective conductor current collectors
- Table 7 – Derating factors for cables wound on drums [Go to Page]
- 12.7.4 Removable current collectors with a disconnector function
- 12.7.5 Clearances in air
- 12.7.6 Creepage distances
- 12.7.7 Conductor system sectioning
- 12.7.8 Construction and installation of conductor wire, conductor bar systems and slip-ring assemblies
- 13 Wiring practices [Go to Page]
- 13.1 Connections and routing [Go to Page]
- 13.1.1 General requirements
- 13.1.2 Conductor and cable runs
- 13.1.3 Conductors of different circuits
- 13.1.4 AC circuits – Electromagnetic effects (prevention of eddy currents)
- 13.1.5 Connection between pick-up and pick-up converter of an inductive power supply system
- 13.2 Identification of conductors [Go to Page]
- 13.2.1 General requirements
- 13.2.2 Identification of the protective conductor / protective bonding conductor
- 13.2.3 Identification of the neutral conductor
- Figure 16 – Symbol IEC 60417-5019
- Figure 17 – Symbol IEC 60417-5021 [Go to Page]
- 13.2.4 Identification by colour
- 13.3 Wiring inside enclosures
- 13.4 Wiring outside enclosures [Go to Page]
- 13.4.1 General requirements
- 13.4.2 External ducts
- 13.4.3 Connection to moving elements of the machine
- 13.4.4 Interconnection of devices on the machine
- 13.4.5 Plug/socket combinations
- Table 8 – Minimum permitted bending radii for the forced guidingof flexible cables [Go to Page]
- 13.4.6 Dismantling for shipment
- 13.4.7 Additional conductors
- 13.5 Ducts, connection boxes and other boxes [Go to Page]
- 13.5.1 General requirements
- 13.5.2 Rigid metal conduit and fittings
- 13.5.3 Flexible metal conduit and fittings
- 13.5.4 Flexible non-metallic conduit and fittings
- 13.5.5 Cable trunking systems
- 13.5.6 Machine compartments and cable trunking systems
- 13.5.7 Connection boxes and other boxes
- 13.5.8 Motor connection boxes
- 14 Electric motors and associated equipment [Go to Page]
- 14.1 General requirements
- 14.2 Motor enclosures
- 14.3 Motor dimensions
- 14.4 Motor mounting and compartments
- 14.5 Criteria for motor selection
- 14.6 Protective devices for mechanical brakes
- 15 Socket-outlets and lighting [Go to Page]
- 15.1 Socket-outlets for accessories
- 15.2 Local lighting of the machine and of the equipment [Go to Page]
- 15.2.1 General
- 15.2.2 Supply
- 15.2.3 Protection
- 15.2.4 Fittings
- 16 Marking, warning signs and reference designations [Go to Page]
- 16.1 General
- 16.2 Warning signs [Go to Page]
- 16.2.1 Electric shock hazard
- 16.2.2 Hot surfaces hazard
- 16.3 Functional identification
- 16.4 Marking of enclosures of electrical equipment
- Figure 18 – Symbol ISO 7010-W012
- Figure 19 – Symbol ISO 7010-W017
- 16.5 Reference designations
- 17 Technical documentation [Go to Page]
- 17.1 General
- 17.2 Information related to the electrical equipment
- 18 Verification [Go to Page]
- 18.1 General
- 18.2 Verification of conditions for protection by automatic disconnection of supply [Go to Page]
- 18.2.1 General
- 18.2.2 Test 1 – Verification of the continuity of the protective bonding circuit
- 18.2.3 Test 2 – Fault loop impedance verification and suitability of the associated overcurrent protective device
- 18.2.4 Application of the test methods for TN-systems
- Table 9 – Application of the test methods for TN-systems
- 18.3 Insulation resistance tests
- Table 10 – Examples of maximum cable lengths from protective devices to their loads for TN-systems
- 18.4 Voltage tests
- 18.5 Protection against residual voltages
- 18.6 Functional tests
- 18.7 Retesting
- Annexes [Go to Page]
- Annex A (normative) Fault protection by automatic disconnection of supply [Go to Page]
- A.1 Fault protection for machines supplied from TN-systems [Go to Page]
- A.1.1 General
- A.1.2 Conditions for protection by automatic disconnection of the supply by overcurrent protective devices
- Table A.1 – Maximum disconnecting times for TN systems [Go to Page]
- [Go to Page]
- A.1.3 Condition for protection by reducing the touch voltage below 50 V
- A.1.4 Verification of conditions for protection by automatic disconnection of the supply
- Figure A.1 – Typical arrangement for fault loop impedance (Zs) measurement in TN systems
- Figure A.2 – Typical arrangement for fault loop impedance (Zs) measurement for power drive system circuits in TN systems [Go to Page]
- A.2 Fault protection for machines supplied from TT-systems [Go to Page]
- A.2.1 Connection to earth
- A.2.2 Fault protection for TT systems
- A.2.3 Verification of protection by automatic disconnection of supply using a residual current protective device
- Table A.2 – Maximum disconnecting time for TT-systems [Go to Page]
- [Go to Page]
- A.2.4 Measurement of the fault loop impedance (Zs)
- Figure A.3 – Typical arrangement for fault loop impedance (Zs) measurement in TT systems
- Figure A.4 – Typical arrangement for fault loop impedance (Zs) measurement for power drive system circuits in TT systems
- Annex B (informative) Enquiry form for the electrical equipment of machines
- Annex C (informative) Examples of machines covered by this part of IEC 60204
- Annex D (informative) Current-carrying capacity and overcurrent protection of conductors and cables in the electrical equipment of machines [Go to Page]
- D.1 General
- D.2 General operating conditions [Go to Page]
- D.2.1 Ambient air temperature
- D.2.2 Methods of installation
- Table D.1 – Correction factors
- Figure D.1 – Methods of conductor and cable installation independent of number of conductors/cables [Go to Page]
- [Go to Page]
- D.2.3 Grouping
- Table D.2 – Derating factors for Iz for grouping
- Table D.3 – Derating factors for Iz for multicore cables up to 10 mm2 [Go to Page]
- [Go to Page]
- D.2.4 Classification of conductors
- D.3 Co-ordination between conductors and protective devices providing overload protection
- Figure D.2 – Parameters of conductors and protective devices
- Table D.4 – Classification of conductors [Go to Page]
- D.4 Overcurrent protection of conductors
- Table D.5 – Maximum allowable conductor temperatures under normal and short-circuit conditions [Go to Page]
- D.5 Effect of harmonic currents on balanced three-phase systems
- Annex E (informative) Explanation of emergency operation functions
- Annex F (informative) Guide for the use of this part of IEC 60204
- Table F.1 – Application options
- Annex G (informative) Comparison of typical conductor cross-sectional areas
- Table G.1 – Comparison of conductor sizes
- Annex H (informative) Measures to reduce the effects of electromagnetic influences [Go to Page]
- H.1 Definitions [Go to Page]
- H.1.1 apparatus
- H.1.2 fixed installation
- H.2 General
- H.3 Mitigation of electromagnetic interference (EMI) [Go to Page]
- H.3.1 General
- H.3.2 Measures to reduce EMI
- Figure H.1 – By-pass conductor for screen reinforcement [Go to Page]
- H.4 Separation and segregation of cables
- Table H.1 – Minimum separation distances using metallic containment as illustrated in Figure H.2
- Figure H.2 – Examples of vertical separation and segregation
- Figure H.3 – Examples of horizontal separation and segregation
- Figure H.4 – Cable arrangements in metal cable trays
- Figure H.5 – Connections between metal cable trays or cable trunking systems [Go to Page]
- H.5 Power supply of a machine by parallel sources
- H.6 Supply impedance where a Power Drive System (PDS) is used
- Figure H.6 – Interruption of metal cable trays at fire barriers
- Annex I (informative) Documentation / Information
- Table I.1 – Documentation / Information that can be applicable
- Bibliography [Go to Page]