Already a subscriber? 

MADCAD.com Free Trial
Sign up for a 3 day free trial to explore the MADCAD.com interface, PLUS access the
2009 International Building Code to see how it all works.
If you like to setup a quick demo, let us know at support@madcad.com
or +1 800.798.9296 and we will be happy to schedule a webinar for you.
Security check
Please login to your personal account to use this feature.
Please login to your authorized staff account to use this feature.
Are you sure you want to empty the cart?

BS EN 18032:2025 Foodstuff. Quick Method for the Analysis of Multiple Highly Polar Pesticides and their Metabolites in Foodstuff Involving Extraction with Acidified Methanol and Measurement by LC- or IC-MS/MS (QuPPe-Method), 2025
- undefined
- European foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Principle
- 5 Preparation and storage of the samples [Go to Page]
- 5.1 General considerations
- 5.2 Laboratory sample
- 5.3 Treatment of laboratory samples prior to milling
- 5.4 Sample homogenization [Go to Page]
- 5.4.1 General considerations
- 5.4.2 Preparation of homogenates of dried fruit and similar commodities
- Table 1 — Dried fruits/water proportion during homogenization [Go to Page]
- 5.5 Analytical test portion
- 6 Procedure
- Table 2 — Extraction modules
- Table 3 — Clean-up modules
- Table 4 — Dilution modules - exemplary
- Table 5 — Measurement modules
- Table 6 — Quantification modules
- 7 Evaluation of results [Go to Page]
- 7.1 Identification
- 7.2 Calibration and quantification
- 7.3 Calculation of residue levels [Go to Page]
- 7.3.1 Calculation of residue concentrations using external calibration without IL-ISs
- 7.3.2 Calculation of residue concentrations using external calibration and IL-IS
- 7.3.3 Calculation of residue concentration using the standard additions approach
- 7.3.4 Calculation of residue levels of complex residue definitions
- 8 Validity of the method
- Table 7 — Overview of available validation data generated within the frame of inter-laboratory validation studies (successful validation by ≥ 3 laboratories with n = 5 for 2 levels)
- Table 8 — Overview of currently applying MRLs for commodities of plant origin and comparison to the lowest successfully validated levels (LSVLs) within the inter-laboratory study, status as of DATE [11]
- Table 9 — Overview of currently applying MRLs for commodities of animal origin and comparison to the lowest successfully validated levels (LSVLs) within the inter-laboratory study, status as of [11]
- 9 Test report
- 10 Additional information on analysis [Go to Page]
- 10.1 Extraction Time
- 10.2 Scaling
- Annex A (informative) Description of modules
- A.1 Reagents
- Table A.1 — Exemplary concentrations of IL-IS Working Solutions (IL-IS-WSln)
- Table A.2 — Exemplary pipetting scheme for the preparation of calibration standards
- Table A.3 — Exemplary pipetting scheme for standard additions to extract aliquots
- A.2 Apparatuses and utensils
- A.3 Extraction (E) modules
- A.3.1 General
- A.3.2 Module E1: Extraction of 10 g sample with ≥ 80 % moisture
- A.3.2.1 Short description
- A.3.2.2 Procedure
- A.3.2.2.1 Weighing of analytical test portion and water adjustment
- A.3.2.2.2 Addition of IL-IS (recommended)
- A.3.2.2.3 Extraction and centrifugation
- A.3.3 Module E2: Extraction of 10 g sample with 40 % to 80 % moisture, after addition of water
- A.3.3.1 Short description
- A.3.3.2 Procedure
- A.3.3.2.1 Weighing of the analytical test portion and water adjustment
- A.3.3.2.2 Addition of IL-IS (recommended)
- A.3.3.2.3 Extraction and Centrifugation
- A.3.4 Module E3: Extraction of a re-hydratized homogenate of samples with an original moisture content between 15 % and 40 %,
- A.3.4.1 Short description
- A.3.4.2 Procedure
- A.3.4.2.1 Weighing of analytical portion
- A.3.4.2.2 Addition of IL-IS (recommended)
- A.3.4.2.3 Extraction and Centrifugation
- A.3.5 Module E4: Honey
- A.3.5.1 Short description
- A.3.5.2 Procedure
- A.3.5.2.1 Weighing of analytical test portion
- A.3.5.2.2 Addition of IL-IS (recommended)
- A.3.5.2.3 Extraction and Centrifugation
- A.3.6 Module E5a: Extraction of 2 g or 5 g sample with a moisture content < 15 %, after addition of 10 ml water
- A.3.6.1 Short description
- A.3.6.2 Procedure
- A.3.6.2.1 Weighing of analytical test portion and water adjustment
- A.3.6.2.2 Addition of IL-IS (recommended)
- A.3.6.2.3 Extraction and Centrifugation
- A.3.7 Module E5b: Extraction of 2 g or 5 g samples with a moisture content < 15 %, after addition of water, 10 % EDTA and formic acid
- A.3.7.1 Short description
- A.3.7.2 Procedure
- A.3.7.2.1 Weighing of analytical test portion and water adjustment
- A.3.7.2.2 Addition of IL-IS (recommended)
- A.3.7.2.3 Extraction, Centrifugation and Filtration
- A.3.8 Module E6a: Extraction of 10 g sample of animal origin with a moisture content > 30 %, after addition of water
- A.3.8.1 Short description
- A.3.8.2 Procedure
- A.3.8.2.1 Weighing of analytical test portion and adjustment of water
- A.3.8.2.2 Addition of IL-IS (recommended)
- A.3.8.2.3 Extraction and Centrifugation
- A.3.9 Module E6b: Extraction of 10 g sample of animal origin with a moisture content > 30 %, after addition of water, 10 % EDTA and formic acid
- A.3.9.1 Short description
- A.3.9.2 Procedure
- A.3.9.2.1 Weighing of analytical test portion and adjustment of water
- A.3.9.2.2 Addition of IL-IS (recommended)
- A.3.9.2.3 Extraction and Centrifugation
- A.3.10 Module E7: Extraction of 5 g fat samples, with the help of mechanical aids
- A.3.10.1 Short description
- A.3.10.2 Procedure
- A.3.10.2.1 Weighing of analytical test portion
- A.3.10.2.2 Addition of IL-IS (recommended)
- A.3.10.2.3 Extraction, Centrifugation and Filtration
- A.4 Clean-up (C) modules
- A.4.1 General
- A.4.2 Module C0: No clean-up
- A.4.3 Module C1: Freeze-out for the precipitation of poorly soluble co-extractives
- A.4.3.1 Short description
- A.4.3.2 Procedure
- A.4.4 Module C2: Dispersive SPE with C18-sorbent
- A.4.4.1 Short description
- A.4.4.2 Procedure
- A.4.5 Module C3a: Precipitation with acetonitrile
- A.4.5.1 Short description
- A.4.5.2 Procedure
- A.4.6 Module C3b: Precipitation with acetonitrile combined with C18 sorbent
- A.4.6.1 Short description
- A.4.6.2 Procedure
- A.4.7 Module C4: Ultrafiltration using cut-off filters of 5 kDa or 10 kDa (optional)
- A.4.7.1 Short description
- A.4.7.2 Procedure
- A.5 Dilution (DL) Modules
- A.5.1 Short description
- A.5.2 Procedure
- A.5.3 Calculation
- A.6 Measurement (M) Modules
- A.6.1 General
- A.6.2 Module M1: LC-MS/MS (HILIC-column, ESI neg. mode)
- A.6.2.1 Short description
- A.6.2.2 Procedure
- A.6.2.3 Instrumental parameters
- A.6.2.3.1 General
- A.6.2.3.2 Exemplary LC Parameters, M1a (HILIC, ESI-neg.)
- Table A.4
- A.6.2.3.3 Exemplary LC Parameters, M1b (HILIC, ESI-neg.)
- Table A.5
- A.6.2.3.4 Exemplary LC Parameters, M1c (HILIC, ESI-neg.)
- Table A.6
- A.6.2.3.5 Exemplary LC Parameters, M1d (HILIC, ESI-neg.)
- Table A.7
- A.6.2.3.6 Exemplary LC Parameters, M1e (HILIC, ESI-neg.)
- Table A.8
- A.6.2.3.7 Exemplary LC Parameters, M1f (HILIC, ESI-neg.)
- Table A.9
- A.6.3 Module M2: LC-MS/MS (HILIC-column, ESI pos. mode)
- A.6.3.1 Short description
- A.6.3.2 Procedure
- A.6.3.3 Instrumental Parameters
- A.6.3.3.1 General
- A.6.3.3.2 Exemplary LC Parameters, M2a (HILIC, ESI-pos.)
- Table A.10
- A.6.3.3.3 Exemplary LC Parameters, M2b (HILIC, ESI-pos.)
- Table A.11
- A.6.3.3.4 Exemplary LC Parameters, M2c (HILIC, ESI-pos.)
- Table A.12
- A.6.3.3.5 Exemplary LC Parameters, M2d (HILIC, ESI-pos.)
- Table A.13
- A.6.4 Module M3: LC-MS/MS (porous graphitic carbon column, ESI neg. mode)
- A.6.4.1 Short description
- A.6.4.2 Procedure
- A.6.4.3 Instrumental Parameters
- A.6.4.3.1 General
- A.6.4.3.2 Exemplary LC Parameters, M3a (PGC, ESI-neg.)
- Table A.14
- A.6.4.3.3 Exemplary LC Parameters, M3b (PGC, ESI-neg.)
- Table A.15
- A.6.5 Module M4: IC-MS/MS (anion exchange column, ESI neg. mode)
- A.6.5.1 Short description
- A.6.5.2 Procedure
- A.6.5.3 Instrumental Parameters
- A.6.5.3.1 General
- A.6.5.3.2 Exemplary IC Parameters, M4a (Anion Exchange, ESI-neg.)
- Table A.16
- A.6.5.3.3 Exemplary IC Parameters, M4b (Anion Exchange, ESI-neg.)
- Table A.17
- A.6.6 Module M5: IC-MS/MS (cation exchange column, ESI pos. mode)
- A.6.6.1 Short description
- A.6.6.2 Procedure
- A.6.6.3 Instrumental Parameters
- A.6.6.3.1 General
- A.6.6.3.2 Exemplary IC Parameters, M5a (Cation Exchange, ESI-pos.)
- Table A.18
- A.6.6.3.3 Exemplary IC Parameters, M5b (Cation Exchange, ESI-pos.)
- Table A.19
- A.6.7 MS-Conditions: Details and general remarks
- A.6.7.1 MS-instrument parameters for measurements in ESI neg. mode
- A.6.7.1.1 General
- A.6.7.1.2 Exemplary MS parameters ESI-neg. A
- Table A.20
- A.6.7.1.3 Exemplary MS parameters ESI-neg. B
- Table A.21
- A.6.7.1.4 Exemplary MS parameters ESI-neg. C
- Table A.22
- A.6.7.1.5 Exemplary MS parameters ESI-neg. D
- Table A.23
- A.6.7.1.6 Exemplary MS parameters ESI-neg. E
- Table A.24
- A.6.7.1.7 Exemplary MS parameters ESI-neg. F
- Table A.25
- A.6.7.2 MS-instrument parameters for measurements in ESI pos. mode
- A.6.7.2.1 General
- A.6.7.2.2 Exemplary MS parameters ESI-pos. A
- Table A.26
- A.6.7.2.3 Exemplary MS parameters ESI-pos. B
- Table A.27
- A.6.7.2.4 Exemplary MS parameters ESI-pos. C
- Table A.28
- A.6.7.3 Compound mass transitions and remarks (ESI neg. mode)
- Table A.29
- A.6.7.4 Compound mass transitions and hints (ESI pos.)
- Table A.30
- A.7 Quantification (Q) Modules
- A.7.1 Module Q1a: Quantification using calibration based on external standards in solvent (solvent-based without the use of IL-IS)
- A.7.1.1 General
- A.7.1.2 Procedure
- A.7.1.3 Calibration and calculation
- A.7.2 Module Q1b: Quantification using calibration based on external standards in solvent and IL-IS (solvent-based calibration using IL-IS)
- A.7.2.1 General
- A.7.2.2 Procedure
- A.7.2.3 Calibration and calculation
- A.7.3 Module Q2a: Quantification using calibration based on external standards in extracts of generic residue-free samples (matrix based calibration without the use of IL-IS)
- A.7.3.1 General
- A.7.3.2 Procedure
- A.7.3.3 Calibration and calculation
- A.7.4 Module Q2b: Quantification using calibration based on external standards in extracts of generic residue-free samples and IL-IS (matrix-based calibration using IL-IS)
- A.7.4.1 General
- A.7.4.2 Procedure
- A.7.4.3 Calibration and calculation
- A.7.5 Module Q3a: Quantification using calibration based on external standards in extracts of residue-free samples of the same matrix type (matrix matched calibration without the use of IL-IS)
- A.7.5.1 General
- A.7.5.2 Procedure
- A.7.5.3 Calibration and calculation
- A.7.6 Module Q3b: Quantification using calibration based on external standards in extracts of residue-free samples of the same matrix type, with IL-IS (matrix-matched calibration using IL-IS)
- A.7.6.1 General
- A.7.6.2 Procedure
- A.7.6.3 Calibration and calculation
- A.7.7 Module Q4a: Quantification using external standards spiked on portions of residue-free control samples and passing through the entire procedure not using IL-IS, (procedural calibration without IL-IS)
- A.7.7.1 General
- A.7.7.2 Procedure
- A.7.7.3 Calibration and calculation
- A.7.8 Module Q4b: Quantification using external standards spiked on portions of residue-free control samples and passing through the entire procedure using IL-IS, (procedural calibration using IL-IS)
- A.7.8.1 General
- A.7.8.2 Procedure
- A.7.8.3 Calibration and calculation
- A.7.9 Module Q5: Quantification using standard addition to the final extract (optionally using IL-IS if available) (standard additions on extract aliquots)
- A.7.9.1 General
- A.7.9.2 Procedure
- A.7.9.3 Calibration and calculation
- A.7.10 Module Q6: Quantification using standard addition to separate test portions of the sample (optionally using IL-IS if available) (standard additions on sample portions)
- A.7.10.1 General
- A.7.10.2 Procedure
- A.7.10.3 Calculation
- Annex B (normative) Additional information
- Table B.1 — Preferred combinations of E and C modules for exemplary commodities
- Annex C (informative) Supplementary information on the method
- Annex D (informative) Abbreviations and symbols
- Table D.1 — List of abbreviations and symbols
- Bibliography [Go to Page]